Cable size for 10.5 kw electric shower

Hi all,i recently fitted a 10.5 kw shower,to a 6mm cable feed existing cable .Now the customer says its overheated and could have caused a fire. Standard Shower Rating Watts (kW), Maximum load from the supply Amps . Try not to twist the cable when installing it, this will not reduce its electrical For showers rated at 10.5kW and above a switch capable of handling loads up to 50A is. Triton Martinique 10.5Kw Electric Shower – posted in Electrics: adequate for this rating of shower IMHO, but provided that the cable is in good.

Buy Triton Seville 10.5kW Electric Shower from Amazon.s DIY Tools store. Size Name: 10.5kW. 10.5kW. ?55.04. 7.5kW. ?52.04. 8.5kW. ?44.05. 9.5kW. ? 62.73. Multiple Cable Water Entry Points for Replacement. Rotary Temperature. ELECTRIC SHOWER,GALAXY AQUA 3000M,10.5KW. External Plug Type:UK. Power Rating:10.5kW. Supply Voltage:230V. Cable Size:16mm?. Colour:White..

Triton Topaz T80si Thermostatic Electric Shower 10.5kW at lowest online prices ( checked daily). Shower Cable Size, 10mm. Electric Cable, 10mm. Suitable

Wiring an Electric Shower Electric Power Shower

Quartz Electric is a surface mounted instantaneous electric shower unit which is Min cable size mm2. Max cable run in m. 40/45A. 45A. 9.5kW. 10.5kW. Dimensions Control panel Triton T300si Wireless 10.5kW Electric Shower – Satin/Chrome with the remote power pack without using a cable. It can be.

Triton Opal 3 10.5kW White Shower Electric Shower – Homebase

Triton Opal 3 10.5kW White Shower Electric Shower. Items 1 – 33 of 105 Bristan – Joy ThermoSafe Electric Shower – White. In Stock. rating 5 . Triton – T80z Thermostatic 10.5 kw Electric Shower – Chrome – SP8CHR1ZTHM . as this will explain which size cable you will need for your system. 9.5 KW, 10.5 kW Cable Entry Points. Top, bottom, back Ideal size and shape for replacement installations. • Top entry trims electric shower electric sho w.

Triton Martinique 10.5kW Electric Shower is rated 4.4138 out of 5 by 58 compact, the Triton Martinique 10.5kW shower fits tidily into any size of bathroom. white and chrome-effect casing along with multi water and cable entry points, the. T80Z electric shower. To check the . The installation, supply cable and circuit 45A. 45A unit rating. 7.0kW. 7.5kW. 8.0kW. 8.5kW. 9.0kW. 9.5kW. 10.5kW.

Electrical rating of your shower is on the pack or on the rating plate label. 10.5 kW. 45A. 45A. The current carrying capacity of the cable must be at least that of. Fitting or installing an electric shower covers electrical considerations as well as The ply should also have a cut out for the cable needed to supply power. The MCB at the consumer unit will be determined by the rating of the shower. a 9.5 kW will require a 40 amp MCB and a 10.5kW shower will need a 45amp MCB. Electric showers are rated in kilo watts and the size of the shower in KW s determines the size of the 35 amps so the size of the cable required to install this shower must have a current carrying capacity of at 10.5Kw =10mm/50amp MCB.